The Standard 22 Gyrocompass by Raytheon Anschutz Kiel provides all spare parts and necessary information for its operation. It includes the Std22 Gyrosphere, various PCBs, Service Pack, and optional parts.
For reliability in maritime navigation, the Std 22 Gyrocompass is a premier technology supporting seamless journeys. Opt for the Standard 22 for robust, accurate, and uninterrupted navigation.
Parts of the Standard 22 Gyrocompass
The following list details both basic and optional parts of the device. Refer to the part numbers provided for inquiries, as each product has a unique PN controlling its functions.
Gyro Compass Main Unit – Part Number: 110-233
The cornerstone of the Standard 22 Gyro Compass system, providing precise orientation and guidance. Integrates seamlessly to enhance overall performance.
Includes:
Power Supply PCB – 110-233.X12
Outer Sphere PCB – 110-233.X10
Connection PCB – 110-233.X13
Sensor PCB – 110-233.X11
Encoder – 110-233.X01
Hinge Unit – 110-233.11
Cable Loom – 110-233.28
Terminal PCB with Temperature Sensor – 110-233.X09
Pump Unit – 110-231.40
Heater Unit – 110-231.X01
Outer Sphere Complete – 110-233.X04
Supporting Liquid – 148-162 E01
Distilled Water – 148- 398
Filler Pipe – 148-398.00-002
Set of Gaskets – 110-222.X01
Set of Small Parts – 110-233.X50
Fan – 110-233.00-002
Step Motor – 110-233.47
* Information regarding these sequential part numbers is listed title by title below.
Power Supply PCB – 110-233.X12
Generates necessary voltages for proper functioning. Malfunctions identified through specific error codes displayed on the screen.
Error Codes:
EL 01: Serial connection of Sensor PCB to Power Supply PCB faulty
EL 02: Inductive transmission faulty
EL 03: System voltage on Power Supply PCB faulty
EL 04: Encoder voltage faulty
EL 05: System voltage on Power Supply PCB faulty
Outer Sphere PCB – 110-233.X10
Facilitates accurate voltage transmission to the Gyrosphere, ensuring precise heading data. Specific error codes help diagnose potential issues.
Error Codes:
EL 10 Supporting liquid error EL 11 System voltage (B21.5 ⇒ B21.8) on sensor PCB faulty EL 12 Operating voltage 24V faulty EL 13 Operating voltage 15V faulty EL 14 Heating operating voltage (B21.1 ⇒ B21.4) faulty EL 15 Operating voltage 72V faulty EL 16 Operating voltage 78V faulty for 400 Hz EL 17 Gyro supply 55Veff faulty EL 18 Gyro current faulty EL 19 Pump voltage faulty EL 20 Pump current faulty EL 21 Temperature sensor faulty EL 22 Serial interface MC1 to MC2 faulty EL 23 CAN interface from outer sphere PCB to sensor PCB faulty EL 24 Heating system faulty
Connection PCB – 110-233.X13
Distributes main supply voltage and communication cables within the device. Enables communication between various components.
Error Code:
EL 09 CAN1 and CAN2 operating voltage faulty.
Sensor PCB – 110-233.X11
Manages all device versions, software, and mathematical operations. Integrates essential components for observation and diagnostics.
Error Codes:
EL 06 Encoder faulty EL 07 CAN dialogue from outer sphere PCB to sensor PCB faulty EL 08 Follow-up system faulty
Encoder – 110-233.X01
Processes Gyrosphere information for accurate ship heading. Monitors functionality through specific error codes.
Error Codes:
EL 04 Encoder voltage faulty EL 06 Encoder faulty
Hinge Unit – 110-233.11
Supports the Gyrocompass Container and Gyrosphere, ensuring stability despite ship movements
Cable Loom – 110-233.28
Connects the Outer Sphere PCB to the Terminal PCB, facilitating communication between these components.
Terminal PCB with Temperature Sensor – 110-233.X09
Linked to the Outer Sphere PCB via the Cable Loom, regulating operational temperatures for the Gyrosphere.
Pump Unit – 110-231.40
Facilitates fluid circulation within the Gyrosphere. Monitors voltage and current; regular replacement is advised for optimal performance.
Error Codes:
EL 19 Pump voltage faulty EL 20 Pump current faulty